CO2 control Gastro security basic package
Koolzuur gas alarm CO2 detector, een compleet stekkerklaar beveiligingspakket. Eenvoudig te plaatsen en onderhouden. Beveiliging van personen in 1 optioneel 2 ruimten tegen de gevaren van ontsnapt koolzuurgas.
Description
Kundo xT CO2 CONTROL basic package. Carbon dioxide gas alarm CO2 detector | Complete and ready to plug | Easy to install and maintain.
Complete CO2 Control security package consisting of:
- Warning unit with 3 meter data cable + 220V cable 1.2 meters with EU molded plug
- Sensor unit with data cable 3 meters (Total data cable = 6 meters)
- IP65 junction box with 4 pieces 5-way Wago terminal blocks
- Mounting materials and NL manual (can be downloaded above)
Product description:
Carbon dioxide gas alarm CO2 detector, protection of persons in one maximum two rooms via the control panel / warning unit against the dangers of escaped carbon dioxide. Meets all Arbo requirements such as optical and acoustic pre-alarm at 1.5% and main alarm at 3% carbon dioxide in the air.
Easy to expand with additional components.
Additional signal unit. If there is a second access to the secured room, this is a legal obligation. Switching unit. Useful if the guest toilets are also in the basement. Saves an evacuation during the service.
Extra sensor unit. If there is a second room also with carbon dioxide, e.g. a cold room with beer tap and carbon dioxide bottle storage next to it. Then this is a legal requirement.
Areas of application:
Mainly in the catering industry, protection of persons in beer cellars and/or cold rooms with parts of a beer tap or postmix installation. Storage rooms with carbon dioxide gas CO2 bottles, for example, next to the cold room in which the beer tap installation and barrels are placed. Preparation kitchens with table water systems and simple industrial applications such as fish farms..
Legal maintenance, in accordance with the manufacturer's instructions
After four years (i.e. in the 5th year) exchange the sensor(s) for a manufacturer-calibrated and guaranteed exchange sensor(s)
Are you unsure whether carbon dioxide detection should be installed? Or about installing it yourself? Have a free RI&E drawn up.
Technical Data
Technical data | |
---|---|
Measuring principle | selective IR absorption |
Gas type | carbon dioxide only |
Pre-alarm | 1.5% - optical and acoustic |
Main alarm | 3.0% - optical and acoustic |
Measuring range | 0-5 CO2 Vol. % |
Data transfer | RS 485 interface |
Power supply | 230V / 50Hz |
Legal maintenance | |
Replace sensor | every four years |
Temperature range | |
cooling/freezing | -20 °C to +80 °C |
transport | 0 °C to +40 °C |
Manufacturer's warranty | |
one year | on the entire device |
four years | on the sensor |
Optical indications | |
1 LED green | in operation |
1 LED yellow | fault |
1 LED red | gas alarm |
Dimensions (HxWxD) | 80 x 108 x 80mm |
Housing | IP54 |
Very complete delivery | |
1 sensor | with 3 meter data cable |
1 alarm unit | with 3 meter data cable |
220 volt connection | 1.8 mtr molded plug |
1 connection box | IP65 with 4 Wago clamps |
Mounting material | 2 DIN rail screws plugs |
Optional | |
extra sensor | secure 2nd room |
extra alarm unit | secure 2nd entrance |
data extension cable | maximum 100 mtr |
Connection box | recognizable & error-free |